United Kingdom United Kingdom
European manufacturing

0203 445 0659

vibrator@casadio.fr

ACBMV CASADIO VIBRATION 3 Z.A. LES PRAIRIES
38290 FRONTONAS - FRANCE

Explosion proof vibrator CDX


Specifications of vibrators CDX



Description


The CDX explosion-proof vibrators have been designed for use in industrial processes in a potentially explosive atmosphere. The enclosure of the CDX vibrators is equipped with increased thickness and joints to prevent the transmission of an internal explosion to the surrounding area. The CDX series is characterized and enhanced by many different certifications, depending on the vibrator model.


Power supply


Three-phase voltage from 24V to 690V (limit at 600V for UL and CSA certifications), 50Hz or 60Hz, or single-phase 100-130V 60Hz and 200-240V 50Hz; suitable for use with a PWM inverter from 20Hz to the base frequency with constant torque load profile.


Polarity


2, 4, 6 and 8 poles.


Control


The components that affect protection are 100% accurately controlled and recorded.


Functioning


Continual service (S1) at maximum declared centrifugal force and electric power. Intermittent services are also possible depending on the type of vibrator and the operating conditions. For detailed information, contact our technical assistance office.


Centrifugal force


Range extended to 22400 Kgf. (220 KN), with centrifugal force adjustable from 0 to 100%.


Mechanical protection


Mechanical protection IP66 according to IEC 529, EN 60529.


Protection against mechanical impacts


IK 08 according to IEC 68, EN 50102.


Insulation class


Class F (155°C).


Tropicalization


Standard on all vibrators, with vacuum encapsulation up to size 35, with “drop by drop” trickle system for larger sizes.


Ambient temperature


From -10°C to +40°C.


Vibrator thermal protection


With thermal protector at 130°C for the entire CDX range, or on request with PTC thermistors rated heat detectors 130°C (DIN44081-44082).


Fixing of the vibrator


In all positions and therefore without restriction.


Lubrication


All vibrators are lubricated in the factory and do not require further lubrication if used in normal operating conditions (“FOR LIFE” lubrication). In heavy duty operating conditions periodical re-lubrication may be applied to size 40 and larger.


Terminal box


Large fixed electrical connections. The terminal cover, with increased thickness, is constructed to contain internal explosions. Special shaped terminals allow to fix the power supply cable, protecting it from loosening.


Electric motor


Three-phase and single-phase asynchronous type. Designed for maximum starting torques and torque curves specific to requirements of the vibrating machines. Insulated windings using vacuum encapsulating up to size 35; using the “drop by drop” trickle system with Class H resin for the larger sizes. The rotor is die cast aluminium.


Casing


In high-tensile aluminium alloy up to size 30, in spheroidal cast iron for larger sizes. Patented shape that improves heat dispersion and lowers normal running temperature with full load. An external earthing screw is located on the casing as prescribed by Regulation IEC/EN 60079-0.


Bearing flange


Constructed in spheroidal or grey cast iron. The geometry of the flange transmits the load to the casing uniformly.


Bearings


Custom made with particular geometry, especially designed for this vibrator, suitable to support both high radial and axial loads.


Motor shaft


In treated steel alloy (Isothermic hardening) resistant to stress.


Eccentric weights


Allow continual adjustment of the centrifugal force. This adjustment is realized by a graduated scale, which expresses the centrifugal force as a percentage of the maximum centrifugal force. A patented system (patent N° MO98A000194), called ARS, prevents adjustment errors.


Weight covers


In aluminium alloy.


Painting


Electrostatic surface treatment based on polymerised epoxy polyester powder in oven at 200°C. Tested in salt spray for 500 hours.


Other features


The CDX series is supplied without cable gland and with NPT threaded conduit opening.



Certifications


Certification
Certificate of Conformity n° IECEx UL 09.0034X following standards IEC 61241-0, IEC 61241-1, IEC 60079-0, IEC 60079-1


Certification
Comply with the applicable European Union directives


Certification
GGTN Permit and Gost-R certificate for explosion-proof Ex d: GOST R 51330.0-99, GOST R 51330.1-99, GOST R IEC 61241-1-1-99.


Certification
Certificate: LR 100948. Category: Class I, Groups C,D; Class II, Groups E, F, G. Temperature Class: T4 (135°C). Standards: CAN/CSA C22.2. Zones of use: 1,2*


Certification
Certificate: E129825. Category: Class I, Groups C and D; Class II, Groups E, F and G. Temperature class: T4 (135°C). Regulations: UL N° 674-886. Areas of use: 1, 2*


Certification
Certificate: DEMKO 07 ATEX 0612032 X Category: II 2 G, D, Ex d IIB. Temperature class: 120°C, IP 66 Directives: ATEX 94/9/EC CENELEC EN 60079-0, EN 60079-1, EN 61241-0, EN 61241-1. Areas of use: 1,2,21, 22


Certification
Certification: CMRI and DGMS for Indian. Category: Ex d II B 120°C, IP 66 Regulations: IS2148-2004, IS 13346-2004, IS4691-1985. Areas of use: 1, 2


Certification
Certificate: SIRA 00 ATEX 1026 Category: II 2 G, Ex d IIB. Temperature class: T4 (135°) Directives: ATEX 94/9/EC, CENELEC EN 60079-0, EN 60079-1. Areas of use: 1,2